Minutes, IBIS Quality Teleconference July 29, 2003 TIME AND PHONE FOR NEXT MEETING August 12, 2003 9-10 AM EST (6-7 AM PST) Phone: 408-974-8478 or 800-249-5618 Meeting access: CONFERENCE SERVER 1, Conference ID: 54644 ROLL CALL Adam Tambone adamt@maine.rr.com *Barry Katz bkatz@sisoft.com Benjamin P Silva benjamin.p.silva@intel.com *Bob Ross bob@teraspeed.com Brian Arsenault arsenault_brian@emc.com *Eckhard Lenski Eckhard.Lenski@siemens.com Eric Brock ebrock@sisoft.com Gregory R Edlund gedlund@us.ibm.com Hazem Hegazy hazem_hegazy@mentorg.com John Figueroa jfigueroa@apple.com John Angulo, john_angulo@mentorg.com Katja Koller Katja.Koller@siemens.com Kevin Fisher kfisher@sisoft.com *Kim Helliwell kimgh@apple.com Lance Wang lwang@cadence.com *Lynne Green lgreen@cadence.com Mike Labonte milabont@cisco.com Peter LaFlamme plaflamm@amcc.com Robert Haller rhaller@sisoft.com Roy Leventhal Roy_Leventhal@3com.com Sherif Hammad sherif_hammad@mentorg.com *Todd Westerhoff twesterh@cisco.com Tom Dagostino tom@teraspeed.com *Kazuyoshi Shoji kshohji@hitachi-ul.co.jp *Sadahiro Nonoyama nonoyama@hitachi-ul.co.jp Everyone in attendance marked by * Interested, but have not yet attended: Ralf Bruening Zuken ralf.bruening@zuken.de NOTE: "AR" =3D Action Required. -----------------------MINUTES --------------------------- - Review of minutes for July 15, 2003 Accepted as written. - Announcements EIA Call for Patent Disclosure No company disclosed a patent. - AR Review June 17th minutes uploaded. File name updated per minutes of June 17th. - Opens for new items Bob Ross requested BIRD 82 discussion. This addresses the clamp double-counting issue. Bob Ross sent Bob Haller some IBIS 4.0 test cases. Beta parser is uploaded on IBIS web site. AR: Lynne Green and Bob Haller to submit revised BIRD 82. AR: Bob Haller, upload the IBIS test cases. - Detailed Documentation review Waveform_processing.txt Item 13: S_overshoot_*: Typ value required if used, required for Level 1. Item 14: Add "only when D_overshoot_high and D_overshoot_high not defined." Might also need another sentence for clarification. Item 16: Clarification of static and dynamic limits. Dynamic applies over delta-time, while static applies for all times. Both limits apply together. Delta-time starts when dynamic value crosses static limit. Replace "should" with "must" in several places. VT_curves.txt Require 4 V-t curves for I/O and Output for Level 1, and encouraged for Level 0. Open sink/source/drain buffers would have 2 V-t curves. If Rload=3DR_fixture and Voltage=3DV_fixture, and all other fixture elements (*_dut, *_fixture) are zeroed out, then [Ramp] should match V-t curves. Parser does not check this. Level 1: Require visual check for "ballpark" consistency between Ramp and V-t curves. - Plans and Schedule for next meeting Finish review of VT_curves.txt. Next meeting: August 12, 2003 9-10 AM EST (6-7 AM PST) Phone: 408-974-8478 or 800-249-5618 Meeting access: CONFERENCE SERVER 1, Conference ID: 54644. Meeting ended at 10:00 AM Eastern Time.